All,
I am having some fun with a lab over RTI ratings on plastics. Basically we have a plastic moulding with a component mounted directly on it. The RTI of the plastic is 60C and the component is getting to around 75C actual. I have always looked at the flammability of plastics 5V, V-0, V-1, etc but never the RTI. Is this a just a UL1950 requirement or is it in EN60950 as well. We have done the thermal stress at 70C and all is OK. They are suggesting doing the ball pressure test at 125C, however, I have only used this for qualifying mains transformer bobbins, etc. Regards Tony Reynolds Pitney Bowes +44 (0) 1279 449479 +44 (0) 1279 449118 [email protected] ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Michael Garretson: [email protected] Dave Heald [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: No longer online until our new server is brought online and the old messages are imported into the new server.