The EN 301 489-1 with the other parts is intended as Harmonized standards for RTTE directive that will be give precedence on other EMC standards, EN 300 339 shall be used only if don't exist a product EMC standards. The EN 301 489-1 V1.2.1 shall not be used stand alone without another part of the EN 301 489 series (2...27). The new EN 301 489-1 V1.3.1 will be used in standalone basis for product for which don't exist a dedicate parts and will be substitute the old EN 300 339.
Bye
PAolo
7:23 9/24/01 +0000, you wrote:

Hi all,

Take a look on the standards below. It seems that they cover the same technical
EMC issues. Am I right and if so, why these two standards ?


EN 301 489-01: V1.2.1 (07-2000)
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic
Compatibility (EMC) standard for radio equipment and services; Part 1: Common
technical requirements


EN 300 339:1998 (05-1998)
Electromagnetic compatibility and radio spectrum (ERM); General electromagnetic
compatibility (EMC) for radio communications equipment


Best regards
Amund Westin, Oslo/Norway

--
Get your firstname@lastname email for FREE at http://Nameplanet.com/?su

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        [email protected]
     Dave Heald                [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
No longer online until our new server is brought online and the old messages are imported into the new server.


----------
Paolo Gemma
Siemens Information and Communication Network spa
Microwave Networks MW R&D NSA EMC
SS Padana sup. KM 158 20060 Cassina de'Pecchi (MI) Italy
phone +39 02 9526 6587    fax +39 02 9526 6203
mobile +39 348 3690185
e-mail [email protected]

----------

Reply via email to