Date: Wed, 08 Aug 2001 12:13:38 +0200
To: umbdenst...@sensormatic.com
From: Paolo Gemma <paolo.ge...@icn.siemens.it>
Subject: RE: ETSI EMC Standard

I am involved in ETSI
The change was drive by IEC 61000-4-3 that approved this modification to the basic standards. A similar change is also in the ETSI standards EN 300 386 regarding the non radio telecommunication equipments.
Ciao
Paolo
At 01:19 PM 8/7/01 -0400, you wrote:

Regarding the change in the standard, has anyone started to look into an
upgrade to their compact chambers for stre-e-e-etching the frequency to 2
GHz?  If so, what upgrades did you find most cost effective for

*       signal generator
*       amplifier
*       antenna
*       sensor
*       e-field probe
*       chamber lining modifications

Perhaps we can develop a database of options and trade-offs before we need
to spend the big bucks.

Don Umbdenstock
Sensormatic ?


> ----------
> From:         wo...@sensormatic.com[SMTP:wo...@sensormatic.com]
> Reply To:     wo...@sensormatic.com
> Sent:         Tuesday, August 07, 2001 10:15 AM
> To:   emc-p...@majordomo.ieee.org
> Subject:      ETSI EMC Stadard
>
>
> The final draft of the proposed revision of ETSI EN 301 489-1 is in the
> voting stage. This standard sets the emissions and immunity requirements
> for
> most all transmitters. A major change has been made to the radiated
> immunity
> requirements by adding the frequencies between 1400 MHz and 2000 MHz. I
> was
> told that this change is being driven by CISPR and may be based upon a
> CISPR
> standard. Does anyone have any information in this regard?
>
> Richard Woods
>
> -------------------------------------------
> This message is from the IEEE EMC Society Product Safety
> Technical Committee emc-pstc discussion list.
>
> Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/
>
> To cancel your subscription, send mail to:
>      majord...@ieee.org
> with the single line:
>      unsubscribe emc-pstc
>
> For help, send mail to the list administrators:
>      Michael Garretson:        pstc_ad...@garretson.org
>      Dave Heald                davehe...@mediaone.net
>
> For policy questions, send mail to:
>      Richard Nute:           ri...@ieee.org
>      Jim Bacher:             j.bac...@ieee.org
>
> All emc-pstc postings are archived and searchable on the web at:
>     http://www.rcic.com/     click on "Virtual Conference Hall,"
>

-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     majord...@ieee.org
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Michael Garretson:        pstc_ad...@garretson.org
     Dave Heald                davehe...@mediaone.net

For policy questions, send mail to:
     Richard Nute:           ri...@ieee.org
     Jim Bacher:             j.bac...@ieee.org

All emc-pstc postings are archived and searchable on the web at:
    http://www.rcic.com/     click on "Virtual Conference Hall,"


----------
Paolo Gemma
Siemens Information and Communication Network spa
Microwave Networks MW R&D NSA EMC
SS Padana sup. KM 158 20060 Cassina de'Pecchi (MI) Italy
phone +39 02 9526 6587    fax +39 02 9526 6203
mobile +39 348 3690185
e-mail paolo.ge...@icn.siemens.it

----------


----------
Paolo Gemma
Siemens Information and Communication Network spa
Microwave Networks MW R&D NSA EMC
SS Padana sup. KM 158 20060 Cassina de'Pecchi (MI) Italy
phone +39 02 9526 6587    fax +39 02 9526 6203
mobile +39 348 3690185
e-mail paolo.ge...@icn.siemens.it

----------

Reply via email to