Date: Wed, 08 Aug 2001 12:13:38 +0200
To: umbdenst...@sensormatic.com
From: Paolo Gemma <paolo.ge...@icn.siemens.it>
Subject: RE: ETSI EMC Standard
I am involved in ETSI
The change was drive by IEC 61000-4-3 that approved this modification to
the basic standards.
A similar change is also in the ETSI standards EN 300 386 regarding the
non radio telecommunication equipments.
Ciao
Paolo
At 01:19 PM 8/7/01 -0400, you wrote:
Regarding the change in the standard, has anyone started to look into an
upgrade to their compact chambers for stre-e-e-etching the frequency to 2
GHz? If so, what upgrades did you find most cost effective for
* signal generator
* amplifier
* antenna
* sensor
* e-field probe
* chamber lining modifications
Perhaps we can develop a database of options and trade-offs before we need
to spend the big bucks.
Don Umbdenstock
Sensormatic ?
> ----------
> From: wo...@sensormatic.com[SMTP:wo...@sensormatic.com]
> Reply To: wo...@sensormatic.com
> Sent: Tuesday, August 07, 2001 10:15 AM
> To: emc-p...@majordomo.ieee.org
> Subject: ETSI EMC Stadard
>
>
> The final draft of the proposed revision of ETSI EN 301 489-1 is in the
> voting stage. This standard sets the emissions and immunity requirements
> for
> most all transmitters. A major change has been made to the radiated
> immunity
> requirements by adding the frequencies between 1400 MHz and 2000 MHz. I
> was
> told that this change is being driven by CISPR and may be based upon a
> CISPR
> standard. Does anyone have any information in this regard?
>
> Richard Woods
>
> -------------------------------------------
> This message is from the IEEE EMC Society Product Safety
> Technical Committee emc-pstc discussion list.
>
> Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
>
> To cancel your subscription, send mail to:
> majord...@ieee.org
> with the single line:
> unsubscribe emc-pstc
>
> For help, send mail to the list administrators:
> Michael Garretson: pstc_ad...@garretson.org
> Dave Heald davehe...@mediaone.net
>
> For policy questions, send mail to:
> Richard Nute: ri...@ieee.org
> Jim Bacher: j.bac...@ieee.org
>
> All emc-pstc postings are archived and searchable on the web at:
> http://www.rcic.com/ click on "Virtual Conference Hall,"
>
-------------------------------------------
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
majord...@ieee.org
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Michael Garretson: pstc_ad...@garretson.org
Dave Heald davehe...@mediaone.net
For policy questions, send mail to:
Richard Nute: ri...@ieee.org
Jim Bacher: j.bac...@ieee.org
All emc-pstc postings are archived and searchable on the web at:
http://www.rcic.com/ click on "Virtual Conference Hall,"
----------
Paolo Gemma
Siemens Information and Communication Network spa
Microwave Networks MW R&D NSA EMC
SS Padana sup. KM 158 20060 Cassina de'Pecchi (MI) Italy
phone +39 02 9526 6587 fax +39 02 9526 6203
mobile +39 348 3690185
e-mail paolo.ge...@icn.siemens.it
----------
----------
Paolo Gemma
Siemens Information and Communication Network spa
Microwave Networks MW R&D NSA EMC
SS Padana sup. KM 158 20060 Cassina de'Pecchi (MI) Italy
phone +39 02 9526 6587 fax +39 02 9526 6203
mobile +39 348 3690185
e-mail paolo.ge...@icn.siemens.it
----------