forwarding for gsemin...@nuera.com ____________________Reply Separator____________________ Subject: RE: T3 Author: "Seminsky; George" <gsemin...@nuera.com> List-Post: emc-pstc@listserv.ieee.org Date: 2/8/01 7:54 AM
For whatever it is worth, I believe that T3 interfaces do not have to undergo NEBS GR-1089 Lightning and AC Power Fault testing whereas T1 interfaces do. The reason being that T3 interfaces are not connected to outside lines and therefore are not exposed to environmental nasties. George Seminsky Compliance Engineering Nuera Communications. Inc. 10445 Pacific Center Court San Diego, CA 92121 Ph 858 625 9220 X4410 Fx 858 625 2422 www.nuera.com -----Original Message----- From: David Gelfand [mailto:gelf...@memotec.com] Sent: Thursday, February 08, 2001 7:27 AM To: emc-p...@ieee.org Subject: T3 Has anyone had any experience with safety approvals to UL 1950 of T3 interfaces over coaxial cable - are power line cross tests required? Thanks in advance, David. David Gelfand Regulatory Approvals Memotec Communications Inc. Montreal Canada ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. To cancel your subscription, send mail to: majord...@ieee.org with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Jim Bacher: jim_bac...@mail.monarch.com Michael Garretson: pstc_ad...@garretson.org For policy questions, send mail to: Richard Nute: ri...@ieee.org