Hello all,
I have a problem regarding E and H field generation inside a TEM cell. I have built a standard cell with Zw of 150 Ohms, which I need to generate a known magnetic field strength around 90 MHz. The separation of the top and bottom conductor is 25 cm, the overall length is about 130 cm.
But I don't get the expected results, only at lower frequencies up to 20 MHz the results are usable. At higher frequencies I suspect that I get a standing wave inside my room, or that the cell dimensions in itself are so large compared to the wavelength, that I get an unwanted resonance inside the cell.
I have been looking for material about this in the 'net, but so far I have not found pay dirt.....
What am I missing here??? Greets Jochen Feldhaar Telejet GmbH ------------------------------------------- This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://ieeepstc.mindcruiser.com/ Click on "browse" and then "emc-pstc mailing list"