To all,

       I was wondering if anyone has any experience in the correlation of
results of MIL-STD-461 C RE02 versus MIL-STD-461E RE102.   MIL-STD-461 C
uses a current probe and measures current while MIL-STD-461 E uses LISN's
and measures voltage. More specifically, would a power supply that met
MIL-STD-461C RE02 meet MIL-STD-461E RE102 if all other things were
unchanged.  Also has anyone any experience with correlating  MIL-STD-461C
CS01 versus  MIL-STD-461E CS101.  
       I think what I am trying to find out is; has the MIL-STD-461E version
turned out to be more stringent or less stringent in the areas of RE102 and
CS101.