Ian
You won't find the 61000-4-X standards on the OJ list because they are
"only" methods with (typically) a range of test levels and pass criteria,
>from which the actual product requirements are then intended to be
specifically chosen and referenced in teh product-specific standards.
Regards
John Allen,
Technical Consultant
EMC and Safety Engineering
ERA Technology Ltd.
Cleeve Road
Leatherhead
Surrey KT22 7SA
UK
Tel: +44-1372-367025 (Direct)
+44-1372-367000 (Switchboard)
Fax: +44-1372-367102
From: Gordon,Ian [mailto:[email protected]]
Sent: 23 July 2003 08:24
To: 'Alan E Hutley'; Emc-Pstc Discussion Group
Subject: RE: NEW EMC Standards
Alan et al
I had a look at the OJ link you sent to check that I had the latest versions
of the standards I use. However, the document doesn't include the 61000-4-x
EMC immunity standards. Are they listed elsewhere?
Ian Gordon
From: Alan E Hutley [mailto:[email protected]]
Sent: 22 July 2003 16:42
To: Emc-Pstc Discussion Group
Subject: NEW EMC Standards
Hi Group
New list of EMC Standards in OJ.
http://europa.eu.int/eur-lex/en/dat/2003/c_172/c_17220030722en00020015.pdf
Cheers
Alan E Hutley
EMC & Compliance journal
www.compliance-club.com
_____________________________________________________________________
This e-mail has been scanned for viruses by MCI's Internet Managed Scanning
Services - powered by MessageLabs. For further information visit
http://www.mci.com
_____________________________________________________________________
This e-mail has been scanned for viruses by MCI's Internet Managed Scanning
Services - powered by MessageLabs. For further information visit
http://www.mci.com
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Ron Pickard: [email protected]
Dave Heald: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]
Jim Bacher: [email protected]
Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc
_____________________________________________________________________
This e-mail has been scanned for viruses by MCI's Internet Managed Scanning
Services - powered by MessageLabs. For further information visit
http://www.mci.com
*************************************************************************
Copyright ERA Technology Ltd. 2003. (www.era.co.uk). All rights reserved.
The information supplied in this Commercial Communication should be treated
in confidence.
No liability whatsoever is accepted for any loss or damage
suffered as a result of accessing this message or any attachments.
_____________________________________________________________________
This e-mail has been scanned for viruses by MCI's Internet Managed Scanning
Services - powered by MessageLabs. For further information visit
http://www.mci.com
This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.
Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/
To cancel your subscription, send mail to:
[email protected]
with the single line:
unsubscribe emc-pstc
For help, send mail to the list administrators:
Ron Pickard: [email protected]
Dave Heald: [email protected]
For policy questions, send mail to:
Richard Nute: [email protected]
Jim Bacher: [email protected]
Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc