I have been requested by UL-HongKong to the blocked ventillation abnormal testing with all vents on all side blocked simultaneously. My previous experience has been that one side is blocked at a time. Blocking more than one side at a time was considered multiple faults. If it passes blocking all vents at once shortens test time, but is this method necessary?
What is the experience of others? Bob Johnson ITE Safety This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ieee-pses.org/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc