Dear all,
I have a question regarding on OATS measurement (3m site, 30MHz to 1000MHz), I
hope someone could help me on this issue.
Currently my company is undergoing a accreditation porcess and the accreditor
is asking on the method of testing to overcome the issue of the noise floor
covering the signal generate from the EUT (i.e. Radio station signal ).
We have propose to measure the signal from EUT in an aechoic chamber and use a
signal generator to simulate the signal with a change of frequency (i.e.
10kHz) to avoid the signal being block by the noise floor and re-measure the
signal on OATS.
This method is rejected by the assessor and asking to provide an alternative
method. Could someone provide the solution, thanks!!!

Best Regards,

emc_st