Ed:  Was just checking to see if you guys were awake!
 
Jim

From: Price, Ed [mailto:[email protected]]
Sent: Thursday, March 04, 2004 9:51 AM
To: 'Jim Ericson'
Subject: RE: Sorenson Power Supply




From: Jim Ericson [mailto:[email protected]]
Sent: Wednesday, March 03, 2004 6:52 PM
To: Chris Maxwell; [email protected]
Subject: RE: Sorenson Power Supply


Chris:
 
I've got a similar (different amperage version) Sorensen.  We blew it last
year during an ESD test (it was supplying power to the EUT).  I managed to
obtain pieces of the original manual, and finally repaired it.  Turned out to
be a blown Op Amp IC.  Give me a call at work.
 
Jim Ericson
Acme Testing Company
Acme, Washington
(NE corner of the US)
[email protected]
tel. (360) 595-2785 
 

 
 

Jim:

What's in a man's sig is nearly sacred, but...............
Is there some odd geographical anomaly that I don't understand, or, Alaska
notwithstanding, I sure thought Washington was in the NW corner. <g>
 
Ed
 

Ed Price 
[email protected]         WB6WSN 
NARTE Certified EMC Engineer & Technician 
Electromagnetic Compatibility Lab 
Cubic Defense Applications 
San Diego, CA  USA 
858-505-2780  (Voice) 
858-505-1583  (Fax) 
Military & Avionics EMC Is Our Specialty 

 


Reply via email to