Chris:
 
I've got a similar (different amperage version) Sorensen.  We blew it last
year during an ESD test (it was supplying power to the EUT).  I managed to
obtain pieces of the original manual, and finally repaired it.  Turned out to
be a blown Op Amp IC.  Give me a call at work.
 
Jim Ericson
Acme Testing Company
Acme, Washington
(NE corner of the US)
[email protected]
tel. (360) 595-2785


From: [email protected]
[mailto:[email protected]]On Behalf Of Chris Maxwell
Sent: Wednesday, March 03, 2004 7:04 AM
To: [email protected]
Subject: Sorenson Power Supply



Good people of the group,

 

Not a compliance issue; but an engineering issue in general.

 

I done blew up my Sorenson DCR40-40B DC power supply.  Does anybody know where
I can get a manual or schematic for such a beast.  

 

Alternatively, would anybody know of a repair person or facility in the
NorthEast USA that would want to take on such a beast.  The only location that
I was able to find was in Texas.  

 

Thanks,

 

Chris Maxwell

Design Engineer

Nettest


Reply via email to