Chris: I've got a similar (different amperage version) Sorensen. We blew it last year during an ESD test (it was supplying power to the EUT). I managed to obtain pieces of the original manual, and finally repaired it. Turned out to be a blown Op Amp IC. Give me a call at work. Jim Ericson Acme Testing Company Acme, Washington (NE corner of the US) [email protected] tel. (360) 595-2785
From: [email protected] [mailto:[email protected]]On Behalf Of Chris Maxwell Sent: Wednesday, March 03, 2004 7:04 AM To: [email protected] Subject: Sorenson Power Supply Good people of the group, Not a compliance issue; but an engineering issue in general. I done blew up my Sorenson DCR40-40B DC power supply. Does anybody know where I can get a manual or schematic for such a beast. Alternatively, would anybody know of a repair person or facility in the NorthEast USA that would want to take on such a beast. The only location that I was able to find was in Texas. Thanks, Chris Maxwell Design Engineer Nettest