They also exhibit little contact bounce.


Regards,

Peter L. Tarver, PE
[email protected]

> From: [email protected] [mailto:[email protected]]
> Sent: Wednesday, February 25, 2004 8:21 AM
> To: [email protected];
> [email protected]
> Subject: RE: dry circuit questions
>
>
> When switching a
> dry relay there is often a "runt" pulse that
> occurs when a plasma forms
> before the contacts are quite close.
> Mercury
> relays seem to be largely
> immune to this.
>
>    Dave Cuthbert
>    Micron Technology
>