Does anyone know of equipment that can perform a gated measurement of a burst of 50 kHz, 1.5 ms duration with a 50 Hz rep rate.
The equipment that I currently have can perform gating with RBW greater than 1 kHz. I need to use an RBW of 200-300 Hz to determine characteristics of interest 1 kHz away from my 50 kHz signal. The setup time is not compatible with the RBW. Have I bumped into the laws of physics or the design limitation of the piece of equipment? I am currently working with an Agilent E7401A with gating option 1D6. Any experiences related to gated measurements would be appreciated. Best regards, Don Umbdenstock Sensormatic This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ieee-pses.org/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc