Hi Jules,

The ETS 300 440 has now changed into the EN 300 440. This is indeed the
standard for low power devices in this frequency band and with this standard
you can show that your product fulfils the R&TTE requirement to make effective
use of the spectrum. Besides this there are also requirements for safety and
EMC. For safety you can use the EN 60950 and for EMC you can use the EN
301489-1&3 to show compliance with the R&TTE directive.


Telefication is one of the leading suppliers of worldwide radio and telecom
approvals.
Designated as European Notified Body for the EMC Directive, R&TTE Directive
and the Marine Equipment Directive.
Designated as American FCC Telecommunication Certification Body with full
scope.
Designated as CAB Canada (FCB) for certification of Radio Equipment to the
requirements of Industry Canada.
Designated as CAB Japan for the certification of Radio Equipment and
Telecommunication Terminal Equipment to the Japanese requirements.
Designated as CAB Switzerland for the certification of Radio Equipment and TTE.
Designated as CAB New Zealand and CAB Australia for the certification of TTE.
For other approvals we are your intermediary to the local authorities (our
Liaison services).
Test facilities and experienced engineers are in house available (our
Laboratory services).
Certification and audits of ISO 9000-series based quality systems (our System
Certification services).
 
 

With Kind Regards

Henry Rutjes
Manager Sales & Liaison 
 
*       Telefication bv
        Edisonweg 12 A
      6902 PK Zevenaar
      The Netherlands
(  + 31 316 583 180
 2  + 31 316 583 189
(       + 31 651 182 400 
<       [email protected]
(  http://www.telefication.com/


From: jules [mailto:[email protected]]
Sent: maandag 15 maart 2004 19:11
To: [email protected]
Subject: 10.5 to 10.55 GHz radar device


 We have had an enquiry into testing a SRD operating between 10.5 and 10.55
GHz it is used to find the speed of items moving past it. Basically a swing
speed indicator ! Golf, tennis, etc etc.

 I have looked into the various stds, but can't really find one that fits,
it is using PIR type technology, but it isn't as such a movement or alarm
detector. I found ETS 300-440 was closest.

 The product is licensed for use in USA, but looks to be operating outside
of the EU reg's.

 I'd appreciate any input from the many forum members in EU mainly,  on
whether this device can be licensed or not, I have suggested the importer
contact OFCOM, but in the mean time, one to puzzle over ?

  Many thanks

    Jules


This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ieee-pses.org/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ieee-pses.org/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc

Reply via email to