Werlatone directional couplers are based on a transformer design, with a
whopping big block of ferrite used as the sensing element. Unlike wall-style
directional couplers, one thing you must NEVER do is exceed the power rating
of the coupler. Even a short-term overload can change the nature of the
ferrite, and there goes your calibration. Not that I'm complaining about
Werlatone; used within their ratings, they last forever.

BTW, urban legend has it that the name comes from the founder's name;
something like Werla or Werlat.

Ed

Ed Price
[email protected]     WB6WSN
NARTE Certified EMC Engineer & Technician
Electromagnetic Compatibility Lab
Cubic Defense Applications
San Diego, CA USA
858-505-2780 (Voice)
858-505-1583 (Fax)
Military & Avionics EMC Is Our Specialty






________________________________

        From: hansm [mailto:[email protected]]
        Sent: Wednesday, September 08, 2004 11:43 AM
        To: [email protected]
        Subject: Thanks, Re: Directional couplers


        Thanks!

        I got the info I needed!

        Hans Mellberg
        Engineering Manager
        BACL, a TCB and an EU CAB
        230 Commercial Street
        Sunnyvale CA 94085 USA
        408-732-9162 x38
        408-732-9164 fax


                ----- Original Message -----
                From: [email protected]
                To: [email protected] ; [email protected] ;
[email protected]
                Sent: Wednesday, September 08, 2004 11:23 AM
                Subject: RE: Directional couplers


                John and Hans,
                Thanks for the good reference. The Werlatone directional
couplers look very nice. Here is a link to the Werlatone website:
http://www.werlatone.com/index.cfm?area=0&pageid=12

                Sounds like an old-time electronic company name and it is
easy to remember. This comes to mind: But a Werlatone solid state electronic
organ today and get 25% off! Featuring 75 transistors! No more tubes to
replace!

                     Dave Cuthbert
                     Micron Technology


                -----Original Message-----
                From: [email protected]
[mailto:[email protected]] On Behalf Of John McAuley
                Sent: Wednesday, September 08, 2004 11:57 AM
                To: hansm; EMC-PSTC
                Subject: RE: Directional couplers


                Hi

                It is Werlatone, Brewster NY. they make a directional
coupler that covers 10 kHz to 1000 MHz in a single unit which is very useful
for EMC test set ups. We have two that are rather old now and have given
very good service. They appear to supply more to the OEM market for
incorporation into other equipment.


                John McAuley
                Compliance Engineering Ireland Ltd
                Ratoath Road
                Ashbourne
                Co Meath
                Ireland
                Tel: +353 1 8256722

                www.cei.ie




This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to