Robert A. Macy <[email protected]> wrote (in 
<[email protected]>) about 'Radiated emission measurement 
below 30MHz', on Mon, 11 Jul 2005:
>Is this allowed?
>
>It was my understanding that one of my clients tried to get a *very* 
>low power intentianal "radiator" [at these frequencies, radiator is a 
>euphemism] through Europe and due to some application there, couldn't 
>even start although the power could not even be measured within 10 
>meters.
> Seriously, there was NOTHING at 10 m.  They saw "intentional radiator" 
>150KHz, and said NO.
>
>Did we use the wrong people?

It's difficult to tell. Was 150 kHz the actual operating frequency or 
did it just emit (marginally) at that frequency? 150 kHz is just above 
the lower end of the LF broadcast band (lower end 148.5 kHz) and it 
could be argued that no intentional radiator can be accepted whose 
operating frequency is in a broadcast band.
-- 
Regards, John Woodgate, OOO - Own Opinions Only.
Deadlines are 90% of deadliness.
http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk


This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas             [email protected]
     Mike Cantwell            [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to