On 12-Nov-2005 Ken Javor asked: >> I wonder what OSHA and CSPI (Center for Science in the Public Interest) had to say about broadcasting half a megawatt of rf power... <<
See FCC Bulletin OET-65. It has the maximum FS from 0.3-1.34 MHz for an uncontrolled access area at 614 volts per meter. This decreases to a bit under 482 V/m at 1.71 MHz. Uncontrolled access areas use 30 minute average. For occupational exposure, the limit is 614 V/m from 0.3 - 3 Mhz, averaged over six minutes. Cortland Richmond KA5S - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/listserv/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc