On 12-Nov-2005 Ken Javor asked:

>>  I wonder what OSHA and CSPI (Center for Science in the Public Interest)
had
to say about broadcasting half a megawatt of rf power... <<

See FCC Bulletin OET-65. It has the maximum FS from 0.3-1.34 MHz for an
uncontrolled access area at 614 volts per meter. This decreases to a bit
under 482 V/m at 1.71 MHz.  Uncontrolled access areas use 30 minute
average.  For occupational exposure, the limit is 614 V/m from 0.3 - 3 Mhz,
averaged over six minutes.


Cortland Richmond
KA5S

-