Hi David,

I am not familiar with the QM-333 standard, but if you're not already familiar
with it, you might
try looking at ETSI's ETS 300019 series of standards (they are simliar to the
USA's NEBS
environmental requirements). There are many parts to that series (some may not
be applicable to your
needs), which are freely downloadable from ETSI's website, one at a time.

Regards,

Ron Pickard
[email protected]



                                                                              
                     
             David.Gelfand@mitectelecom.                                      
                     
             com                                                              
                     
             Sent by: [email protected]                                       
                  To 
                                                 [email protected]            
                     
                                                                              
                  cc 
             11/11/2005 01:14 PM                                              
                     
                                                                              
             Subject 
                                                 India QM-333                 
                     
                                                                              
                     
                                                                              
                     
                                                                              
                     
                                                                              
                     
                                                                              
                     
                                                                              
                     




Hello,

Is there an ETSI equivalent for Indian standard QM-333  "Specification for
environmental testing of
electronic equipments for transmission and switching use" for environmental
category B-2.  Any
information on how to get a copy of this spec would help.

Thanks,

David.

David Gelfand
Product Integrity
Mitec Telecom Inc
Montreal Canada

- ---------------------------------------------------------------- This
message is from the IEEE
Product Safety Engineering Society emc-pstc discussion list. Website:
http://www.ieee-pses.org/


To post a message to the list, send your e-mail to [email protected]


Instructions: http://listserv.ieee.org/listserv/request/user-guide.html


List rules: http://www.ieee-pses.org/listrules.html


For help, send mail to the list administrators:


Scott Douglas [email protected] Mike Cantwell [email protected]


For policy questions, send mail to:


Jim Bacher: [email protected] David Heald: [email protected]


All emc-pstc postings are archived and searchable on the web at:


http://www.ieeecommunities.org/emc-pstc

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to