Hello Kim,

The HP/Agilent 6843/12/13 do not meet he future requirements of EN61000-3-2 as
referenced in IEC 61000-4-7 and does not satisfy the "New" EN/IEC61000-3-3
flicker requirements.

Regards,

Ken Hall 


From: [email protected] [mailto:[email protected]] On Behalf Of Kim Boll Jensen
Sent: Friday, January 27, 2006 12:15 AM
To: EMC PSTC
Subject: Power source

Hi all

I'm looking for a AC power source for EN 61000-3-2 testing. I have a used HP
6813A on hand, but from the data I have it seems that it is not for full
compliance. Before buying it I would like to know if the HP is OK or not.
Have some one experiences with this source and is it OK to use for compliance
testing ?

and what else can be used (a cheap/used will be preferred.

Best regards,

Kim Boll Jensen
Bolls Rådgivning
Ved Gadekæret 11F
DK-3660 Stenløse

Tlf.:  48 18 35 66
Fax:   48 18 35 30
Mobil: 22 99 69 91

E-mail: [email protected]
web: www.bolls.dk

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to