In message <[email protected]>, dated Wed, 15 Mar 2006, 
[email protected] writes
>I assume that OATS will still be the standard, right? If a product's 
>compliance is in question, results from an OATS will take precedence 
>over any other test site such as FARs, T-Cell, etc.. Right? OR, does 
>the data from a FAR correlate so well with an OATS what they are 
>considered equivalent?

This is a complicated matter, and I think it's still not properly 
settled. But OATS will not take precedence; the two methods (OATS and 
FAR) will be equally valid. This does not extend to T-cell, I think.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
2006 is YMMVI- Your mileage may vary immensely.

John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-