One of my military customers asked for BS EN61000-4-2:1995 ESD testing, in
order to satisfy a requirement for the British DEF STAN 59-41 Method DCS10.3.
The EUT is an electronics box that mounts in a ground shelter.
 
Our design engineers are worried about ESD protection of the pins of the large
circular Mil-grade connectors on the rear panel of the box. However, when I
read Paragraphs 8.3.1 and A.5, regarding selection of test points, it seems
like connector pins, which I think are not accessible to the equipment
operator, are exempt from this requirement.
 
Looking for another opinion, I looked at the REO Handbook 9 (
http://www.reo.co.uk), where it referred to a list of exempt and non-exempt
connector pins. However, I can't seem to find such a list in BS
EN61000-4-2:1995.
 
I need a fourth (or more) opinion.
 
Thanks,
 
Ed Price
[email protected]                   WB6WSN
NARTE Certified EMC Engineer & Technician
Electromagnetic Compatibility Lab
Cubic Defense Applications
San Diego, CA USA
858-505-2780 (Voice)
858-505-1583 (Fax)
Military & Avionics EMC Is Our Specialty
 
 
- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc 


Reply via email to