In message <[email protected]>, dated Thu, 2 Nov 2006, Asim Tirmizi <[email protected]> writes >I have a separate question on the subject. > >We are supplying UK cords with 3A, 5A, or 13A fuses. The EUT side plug >is rated 2.5A. The wire gauge is suitable for the respective fuse. >The EUT uses only about 0.5A. Does it matter whether we use a 3A fused >cord vs. a 13A fused cord?
Not from the point of view of safety. The plug fuse is there to protect the cord (only, not the product). But if the EUT is small and light, a 13A cord may be so mechanically assertive that the product can't be positioned easily and may even not stand on its feet properly, if the cord is twisted. A case of the 13 A tail wagging the 0.5 A dog. -- OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk Swine wave - a waveform whose spectrum is exceptionally difficult to calculate. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________