Dear Experts,
      In our ethernet device, by introducing series resistors of value 22
ohms in the Tx / Rx signals we noticed reduction in the emission levels.
Reduction of emission in the ethernet harmonics (175, 200, 225, 250, 275,
300 & 350 MHz) is logical. At the same time we notice reduction of emission
in SDRAM clock harmonics also. (multiples of 59.9 MHz). Why & how this
happens and what to infer from this is not clear to us.

Sincerely

K.Balasubramanian
Project Leader - Hardware.

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Reply via email to