In message 
<e6acec5be8405b4e936c9e9bccac10241b6...@bb-corp-be1.corp.cubic.cub>, 
dated Thu, 26 Apr 2007, "Price, Ed" <[email protected]> writes:

>Do the units of "dBW/MHz" imply that, if I measured using a 10 kHz 
>resolution bandwidth, I would have to add a bandwidth factor of 20 dB 
>to normalize the observed data to a 1 MHz bandwidth?

Looks like it.
> 
>Finally, how does one take a 2 millisecond "average"?

Set your SA 'video filter' to the appropriate bandwidth?
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
There are benefits from being irrational - just ask the square root of 2.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-

This message is from the IEEE Product Safety Engineering Society