>We have found that a complaint CEC power supply to be larger in size 
>and more expensive then a noncompliant one as our power supply vendors 
>have to use better quality core material and the transformer ends up 
>being larger.

This is for a 'linear' power supply (mains transformer and rectifier). 
To reduce the no-load power, the induction (flux density) in the core 
has to go down to 1950 values (like 1 T). That means a bigger core 
and/or more turns on the windings.

V = B*a*w*n

V = voltage across a winding (volts), B = induction (flux density) (in 
tesla), a = core cross-section area (sq. metres), w (omega) = 2*pi* 
frequency (Hz).

The other solution is a switch-mode power supply, which meets the 
energy-saving requirements but adds to the 'EMC smog' by its conducted 
and radiated emissions.
>
>The cost is not insignificant if you have a large volume product which 
>uses a wall wart....

Well, it depends. With the enclosure and mechanical parts of many 
products running out at around 10 times the cost of the electronics 
these days....
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
There are benefits from being irrational - just ask the square root of 2.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Reply via email to