I hope Randolph means this way : 'Dividing the power plane is good and will 
improve the situation but dividing the ground plane will only have negative 
effect.'
 
Bharath



From: Joe Randolph <[email protected]>
To: [email protected]; [email protected]
Sent: Wednesday, 16 January, 2008 7:29:45 PM
Subject: Re: Gnd/Pwr Planes

On 1/16/2008, [email protected] wrote:



What are some of the causes that create breaks or slots in ground or power
planes in multilayer boards? Voltage partitioning comes to mind and closely
spaced vias. Others? 



It is very common to partition the power and ground planes to help control the 
return currents for various subsystems on a board.  The idea is to keep the 
return currents localized within each subsystem and then carefully manage the 
return currents between the subsystems using "bridges" between them.  This 
method can be very effective if done correctly, but it can actually make things 
worse if done incorrectly.




Joe Randolph
Telecom Design Consultant
Randolph Telecom, Inc.
781-721-2848 (USA)
[email protected]
http://www.randolph-telecom.com <http://www.randolph-telecom.com/> 
- ---------------------------------------------------------------- This message 
is from the IEEE Product Safety Engineering Society emc-pstc discussion list. 
Website: http://www.ieee-pses.org/ 


To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities..org/emc-pstc



  _____  

Unlimited freedom, unlimited storage. Get it now 
<http://in.rd.yahoo.com/tagline_mail_2/*http://help.yahoo.com/l/in/yahoo/mail/yahoomail/tools/tools-08.html/>
 
- ---------------------------------------------------------------- This message 
is from the IEEE Product Safety Engineering Society emc-pstc discussion list. 
Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Jim Bacher: [email protected] David Heald: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc


Reply via email to