EN50293 in Table 6 refers to the expected 61000-4-11 for voltage dips and interruptions, but then calls up HD 638, 4.5 for the values to be used. Does anyone know what these values are, or where HD 638 can be obtained from? My web searching has so far only found a draft amendment to it, which does not contain the info I need. Mike Hurley
Director Mead testing ltd [email protected] www.meadtest.com phone 44 (0) 1279 635865 fax 44 (0) 1279 635874 Mead Testing Limited is a company registered in England with company number 4572600 whose registered office is: Unit 25 Mead Park, River Way, Harlow, CM20 2SE. VAT number: 802 3904 59 No virus found in this outgoing message. Checked by AVG. Version: 7.5.519 / Virus Database: 269.22.1/1347 - Release Date: 27/03/08 19:15 - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc