The hardware referred to is the CASSPER correlation analyzer by Scientific
Applications & Research Associates, Inc.  

 

The hardware used the principle of correlation analysis, analyzing the phase
correlation between multiple (minimum 2) test channels. The correlation
determination between channels requires a significant data processing effort
per data and time point. On the state-of-the-art hardware available at the
time the data processing was really too slow for any real-time work, causing a
horrible screen refresh rate in most cases, but it was great for source
finding during bench debugging with some patience. Later hardware and software
upgrades solved some of the processing speed issue, I’m told, but the
evaluation unit I had was too slow for the type of work I was doing. 

 

It was discontinued in 2008 (www.sara.com/EM/cassper/index.html). Maintenance
was available through [email protected] into 2009 according to that page.

 

Cheers

-Robert

 

 

From: Cody Miller [mailto:[email protected]] 
Sent: Wednesday, February 16, 2011 15:40
To: [email protected]
Subject: [PSES] Old EMC Software Called CASPR

 

Hi All,

 

Any of you ever worked with a Radiated emissions software called CASPR. One of
the members of our community is looking for someone familiar with it. I have
never heard of it.

 

http://www.eeweb.com/discussions/caspr/

 

Thanks,

Cody 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://product-compliance.oc.ieee.org/ 
http://product-compliance.oc.ieee.org/> 
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to