> Radiated emissions below 30 MHz.

Over here in the USA, the FCC says:

§ 15.209   Radiated emission limits; general requirements.

(a) Except as provided elsewhere in this subpart, the emissions from an 
intentional radiator shall not exceed the field strength levels specified in 
the following table:
Frequency (MHz) Field strength (microvolts/meter)       Measurement distance 
(meters)
0.009–0.490     2400/F(kHz)     300
0.490–1.705     24000/F(kHz)    30
1.705–30.0      30      30
30–88   100**   3
88–216  150**   3
216–960 200**   3
Above 960       500     3

And over on your side of the pond, it is EN 300 330.

And military ref:
http://www.multilek.ca/Specifications.htm


   Attitude is Mind over Matter. 
If you don't Mind, it doesn't Matter...
This email has been displayed using 100% recycled electrons and 100% pure 
virgin photons.



--- On Thu, 2/3/11, John Woodgate <[email protected]> wrote:

> From: John Woodgate <[email protected]>
> Subject: EMC spectrum 'gaps'
> To: [email protected]
> Date: Thursday, February 3, 2011, 1:24 PM
> I am soon to do a presentation on the
> gaps in the EMC spectrum, where there are no emission limits
> for non-military products. These are:
> 
> Conducted emissions from 105 Hz to 1995 Hz, excluding mains
> harmonics;
> 
> Conducted emissions 2.05 kHz to 9 kHz, and 9 kHz to 150 kHz
> for most products;
> 
> Radiated emissions below 30 MHz.
> 
> Pressure to fill in these gaps has blown up for different
> reasons more or less simultaneously in the last 6 months.
> 
> The thing is, that the audience will include some experts
> on military EMC standards, of which I know little. Are there
> any military standards (US or European) for the above
> emissions?
> -- OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and
> www.isce.org.uk
> John Woodgate, J M Woodgate and Associates, Rayleigh, Essex
> UK
> Plural: data, criteria, phenomena. Singular: datum
> (different meaning: use
> 'data element' for a single item), criterion, phenomenon.
> 'Effect' is a noun,
> 'affect' is a verb (except in psychiatry).
> 
> -
> ----------------------------------------------------------------
> This message is from the IEEE Product Safety Engineering
> Society emc-pstc discussion list. To post a message to the
> list, send your e-mail to <[email protected]>
> 
> All emc-pstc postings are archived and searchable on the
> web at:
> http://product-compliance.oc.ieee.org/
> Graphics (in well-used formats), large files, etc. can be
> posted to that URL.
> 
> Website:  http://www.ieee-pses.org/
> Instructions:  http://listserv.ieee.org/request/user-guide.html
> List rules: http://www.ieee-pses.org/listrules.html
> 
> For help, send mail to the list administrators:
> Scott Douglas <[email protected]>
> Mike Cantwell <[email protected]>
> 
> For policy questions, send mail to:
> Jim Bacher:  <[email protected]>
> David Heald: <[email protected]>
> 


      

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to