On 12/15/2010 11:41, Kunde, Brian wrote:
> Does it make VDRs safer to use them in series with a gas-tube like some
> do with Varistors?

Hi Brian:


Yes.

Today, this is the trend among manufacturers that
want to use a VDR between mains and earth.

And, TC108 is still trying to sort out the requirements
for both devices in such a circuit.


Best wishes for a Merry Christmas,
Rich

-
----------------------------------------------------------------