If you are  Class I, the only production line test required is 2.12 kVdc 
between primary to chassis. 

Peter Merguerian
Go Global Compliance Inc
Tel: 408 4163772
Cel: 408 9313303

Sent from my iPhone

On Sep 30, 2010, at 7:06 AM, "Wordley, Chris" <[email protected]> 
wrote:



        Hi Ian
         
        See annex N of IEC60065. For mains supplies over 150V, the routine 
production test voltages are 2.12kVdc for basic insulation and 3.54kVdc for 
double or reinforced insulation. So you'd normally expect to use 2.12kVdc for 
class I products, unless there are parts of the product emplying class II 
construction?
         
        Chris Wordley

________________________________

        From: [email protected] [mailto:[email protected]] On Behalf Of 
McBurney, Ian [Allen & Heath UK]
        Sent: 30 September 2010 14:55
        To: <mailto:[email protected]> [email protected]
        Subject: Dielectric Strength test voltage level
        
        

        Hello Colleagues;

         

        We have been instructed by NEMKO/MET that the voltage setting for the 
dielectric strength test must be 3.54kV DC for units at the end of the 
production process.

        The products are class 1 audio products type tested to IEC 60065.

        We are unable to do the lower voltage ac test because of the emi 
filtering in the PSU.

        Can anyone tell me how this voltage level was arrived at and why it has 
been increasing over the past decade?

        I am a little concerned that it may be over stressing some components 
and may lead to increased field failures.

         

        Thanks in advance

         

        Ian McBurney.

        Allen & Heath Ltd.

        email: <mailto:[email protected]> 
[email protected]

         

        P Please consider the environment - do you really need to print this 
email? 

        ***LEGAL DISCLAIMER*** 

        This Email and any files transmitted with it are confidential and 
intended solely for the use of the individual to whom or the entity to which 
they are addressed. If you have received this email in error please notify the 
sender immediately. Please note that any views or opinions presented in this 
email are those of the author and do not necessarily represent those of Allen & 
Heath Limited. 

        This email has been checked for the presence of viruses using Sophos AV 
Scanner. Anti-virus updates are downloaded on a daily basis . The recipient 
should also check this email and any attachments for the presence of viruses. 
Allen & Heath Limited accepts no liability for any damage caused by any virus 
transmitted via this email. 

        This email has been sent from Allen & heath Limited, registered in 
England, reg. no:4163451. VAT Number GB 876 3336 94. 

        Registered Address: Kernick Industrial Estate, Penryn, Cornwall. UK. 
TR10 9LU. 

        *** 

         

        -
        ----------------------------------------------------------------
        This message is from the IEEE Product Safety Engineering Society 
emc-pstc discussion list. To post a message to the list, send your e-mail to < 
<mailto:[email protected]> [email protected]>
        
        All emc-pstc postings are archived and searchable on the web at 
<http://www.ieeecommunities.org/emc-pstc> 
http://www.ieeecommunities.org/emc-pstc
        Graphics (in well-used formats), large files, etc. can be posted to 
that URL. 

        Website: <http://www.ieee-pses.org/> http://www.ieee-pses.org/
        Instructions: <http://listserv.ieee.org/request/user-guide.html> 
http://listserv.ieee.org/request/user-guide.html
        List rules: <http://www.ieee-pses.org/listrules.html> 
http://www.ieee-pses.org/listrules.html 

        For help, send mail to the list administrators:
        Scott Douglas < <mailto:[email protected]> 
[email protected]>
        Mike Cantwell < <mailto:[email protected]> [email protected]> 

        For policy questions, send mail to:
        Jim Bacher < <mailto:[email protected]> [email protected]>
        David Heald < <mailto:[email protected]> [email protected]> 

        -
        ----------------------------------------------------------------
        This message is from the IEEE Product Safety Engineering Society 
emc-pstc discussion list. To post a message to the list, send your e-mail to < 
<mailto:[email protected]> [email protected]>
        
        All emc-pstc postings are archived and searchable on the web at 
<http://www.ieeecommunities.org/emc-pstc> 
http://www.ieeecommunities.org/emc-pstc
        Graphics (in well-used formats), large files, etc. can be posted to 
that URL. 

        Website: <http://www.ieee-pses.org/> http://www.ieee-pses.org/
        Instructions: <http://listserv.ieee.org/request/user-guide.html> 
http://listserv.ieee.org/request/user-guide.html
        List rules: <http://www.ieee-pses.org/listrules.html> 
http://www.ieee-pses.org/listrules.html 

        For help, send mail to the list administrators:
        Scott Douglas < <mailto:[email protected]> 
[email protected]>
        Mike Cantwell < <mailto:[email protected]> [email protected]> 

        For policy questions, send mail to:
        Jim Bacher < <mailto:[email protected]> [email protected]>
        David Heald < <mailto:[email protected]> [email protected]> 

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at 
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to