Yes, Bellcore/GR-Core/Verizon/SBC/NEBS all have various
reliability standards and requirements, depending on component
type and end-use installation.

luck,
Brian


From: [email protected] [mailto:[email protected]]On Behalf Of
jeff collins
Sent: Tuesday, July 15, 2008 2:32 PM
To: [email protected]
Subject: Re: Immunity Failures caused by System Burn-In

Group,

We have pinned down some immunity failures that are caused by our
system burn-in process, which is rather robust. Are there any
specific Industry standards for the Burn-in of IT or Telecom
electronic equipment?

Thanks in advance!

Jeff Collins
Regulatory Compliance & Reliability

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc



Reply via email to