Hi,
 
As a sanity check of your shielded enclosure and LISN, conduct your CE test 
without the EUT on, you will know right away if you have a leakage problem.
 
Regards,
 
Dave Garnier
 

David Garnier 
e GE HealthCare 
___________________________________________ 

        David S. Garnier 
        Quality Assurance Technician 
        Quality-Controls-EMC 
        3000 N. Grandview Ave - M/S W-618 
        Waukesha, Wi. 53188 
        Tel: 262.312.7246 
        Cel:  414.899.7580 

 

- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 

Instructions: http://listserv.ieee.org/request/user-guide.html 

List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators: 

Scott Douglas [email protected] Mike Cantwell [email protected] 

For policy questions, send mail to: 

Jim Bacher: [email protected] David Heald: [email protected] 

All emc-pstc postings are archived and searchable on the web at: 

http://www.ieeecommunities.org/emc-pstc 

Reply via email to