Hi experts,
 
A question about the IEC 61010-1 requirements to the bottom (and sides) of a
device cases fire enclosure.
With regards to the bottom there are well explained rules for the design of
the bottom in 9.2.1 Constructional Requirements.
 
I have a device with completely flat bottom without any holes, front and back
is bended 90 degrees to make sides of front/back in the two other sides there
is a small bend up side panel of 22mm all this is formed out of same plate.
 
Now my question is related to the corners where the front/back panels meet the
small side panels all bent upwards, here there is a small gap of 2mm bewteen
the materials. It´s not exactly the bottom but instead in the side so do i
have a problem or will it be OK ?
 
        | |2mm
        | |  __________________________
        | | |
front   | | |  
        | |_|
        |______Bottom of device________
 
I tried to make a drawing (best seen using non proportional font)
 
Hope this is somewhat clear, have a nice day :-)
 
Best regards
Peter 
 
-

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at
http://www.ieeecommunities.org/emc-pstc
Graphics (in well-used formats), large files, etc. can be posted to that URL. 

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


Reply via email to