Hi John, Thanks. I now understand that I will need two meters, one for DC/low frequency and the other for high-frequency. Dave Baron provided me the information off-line for a 2 kHz - 400 kHz Magnetic Field Meter from ETS-Lindgren, which will serve my purpose.
My thanks to all who responded to my query. Regards Ravinder Ajmani HGST, a Western Digital company [email protected] John Woodgate <[email protected]> Sent by: [email protected] 01/04/2013 09:42 AM To [email protected] cc Subject Re: Looking for Gaussmeter for measurements up to 250 kHz In message <of0a53b9f4.0b1f453e-on88257ae9.005bd6d8-88257ae9.005cf...@hgst.com>, dated Fri, 4 Jan 2013, [email protected] writes: >I am looking for a Gaussmeter to measure DC and AC magnetic fields up >to 250 kHz. I have tried searching on line but am unable to find one >which covers such high frequency. I will appreciate any help in >finding the source for Gaussmeter. What values of field strength do you wish to measure? The preferred techniques differ considerably with field strength. You may need to have two meters, one for DC only and another for AC. What is the lowest frequency you actually need to measure? -- OOO - Own Opinions Only. See www.jmwa.demon.co.uk The longer it takes to make a point, the more obtuse it proves to be. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>

