In message <[email protected]>,
dated Thu, 19 Dec 2013, Derek Walton <[email protected]> writes:
I am not a proponent of having all planes tied together, only ever seen
disasters that way. If you allow circuit currents to deliberately on
inadvertently flow in the chassis it becomes a nightmare to control
them.
Planes that are intended to be at zero-voltage reference potential
should meet at ONE point only. That way no unwanted sharing or stealing
of currents occurs. Including in a stack a plane carrying stuff from the
'chassis' seems most unwise.
--
OOO - Own Opinions Only. With best wishes. See www.jmwa.demon.co.uk
Nondum ex silvis sumus
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK
-
----------------------------------------------------------------