In message
<e01290186f74674e949ef859df417fe40d7...@exchange.complianceworldwide.lan>
, dated Tue, 18 Feb 2014, Larry K. Stillings
<[email protected]> writes:
I have a customer whom makes a piece of laboratory equipment that
consists of 4 parts, each part having its own power supply. The
customer would like to claim that they sell a power strip with the
system, and all four power cords plug into the strip and therefore only
one set of power cord tests needs to be performed for Immunity.
For Emissions it is clear per EN 55011 that each power cord must be
tested for conducted emissions, for Immunity it gets a little less
clear. Should each power cord be tested individually for EFT, Surge,
CRFI and VDI, or can I use the customer supplied power strip and
perform the testing once.
If the product is sold as a single item (with the power strip) at an
inclusive price, in Europe it is a 'system' and has to be tested as a
whole, i.e. as if it were all in one box. Conducted emission testing
would be done on the single mains lead from the power strip to the wall
socket.
This is actually much better explained in older versions of the EMC
guide.
--
OOO - Own Opinions Only. With best wishes. See www.jmwa.demon.co.uk
Nondum ex silvis sumus
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK
-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion
list. To post a message to the list, send your e-mail to <[email protected]>
All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html
Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used
formats), large files, etc.
Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>
For policy questions, send mail to:
Jim Bacher: <[email protected]>
David Heald: <[email protected]>