Hi, Has anyone come across this problem. While testing a network switch to EN 55022/24 and FCC Subpart B, the customer insisted that a scrolling "H" must appear on a visual display used as a peripheral of the network switch. Test setup included a number of PCs, mouse, keyboard, and visual display. All of these were auxiliary/peripherals of the EUT (network switch). According to my understanding of both EN 55022 and ANSI 63.4, scrolling "H" is only relevant if the visual display is the EUT. I consulted a few people in the field and they and us were of the same opinion that scrolling "H" is not relevant if the visual display is peripheral/auxiliary equipment. Any additional opinions are welcome. Thanks in advance for any responses.
Regards, David Shidlowsky | Technical Reviewer Address 1 Bat-Sheva St. POB 87, LOD 71100 Israel Tel 972-8-9186113 Fax 972-8-9153101 Mail [email protected]<mailto:[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>