Hi David, We recently encountered this, testing a server in Taiwan for BSMI approvals. We argued that the display is auxiliary equipment, only used to install and debug, and the port would be not populated in final use. They insist not only on scrolling Hs, but testing all screen resolutions to find worst case.
Regards, David David Gelfand Kontron Canada De : itl-emc user group [mailto:[email protected]] Envoyé : 29 avril 2015 02:13 À : [email protected] Objet : [PSES] Scrolling "H" Hi, Has anyone come across this problem. While testing a network switch to EN 55022/24 and FCC Subpart B, the customer insisted that a scrolling "H" must appear on a visual display used as a peripheral of the network switch. Test setup included a number of PCs, mouse, keyboard, and visual display. All of these were auxiliary/peripherals of the EUT (network switch). According to my understanding of both EN 55022 and ANSI 63.4, scrolling "H" is only relevant if the visual display is the EUT. I consulted a few people in the field and they and us were of the same opinion that scrolling "H" is not relevant if the visual display is peripheral/auxiliary equipment. Any additional opinions are welcome. Thanks in advance for any responses. Regards, David Shidlowsky | Technical Reviewer Address 1 Bat-Sheva St. POB 87, LOD 71100 Israel Tel 972-8-9186113 Fax 972-8-9153101 Mail [email protected]<mailto:[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]<mailto:[email protected]>> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)<http://www.ieee-pses.org/list.html> List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]<mailto:[email protected]>> Mike Cantwell <[email protected]<mailto:[email protected]>> For policy questions, send mail to: Jim Bacher <[email protected]<mailto:[email protected]>> David Heald <[email protected]<mailto:[email protected]>> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>