Dear Members, I wonder if I could have your help with table evaluation.
It seems three frequency ranges have to be conducted: 200 MHz - 1 GHz, 1 GHz - 6 GHz, and 6 GHz - 18 GHz. Here are my questions: 1. With the table present, how to keep the transmit antenna 0.1 m above the table? Does a piece of 0.1m Styrofoam work? 2. How to determine the frequency step? "During measurement, frequency steps shall be less than or equal to 0.5 % of the highest frequency used." For the frequency range of 200 MHz - 1 GHz, does the frequency step be less than or equal to 1 GHz x 0.5%? 3. Equations 17-19 look straight forward. However, it will take some time to collect data manually. Does anyone have experience using a software to achieve the task? Thank you very much for your time and I look forward to hearing from you. Best regards, Grace Lin - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>