On 10/19/2015 5:17 PM, Grasso, Charles wrote:
Does anyone know of a gizmo or procedure that provides a standard signal for checking the accuracy of a QP detector in a SA?
Check out http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=667547 Modulation impact on quasi-peak detector response Electromagnetic Compatibility, 1997. IEEE 1997 International Symposium on pp 90-95 You may be able to use their test setup. Cortland Richmond - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>