I got a chance to investigate this further and found that the backlash 
is not delayed, but overshooting when the direction changes.  This was 
with the feed at 25 IPM.  If I set the feed to 10 IPM the problem goes 
away.  What is strange is that it does not overshoot in MDI mode with 
the feed set at 25 IPM.  Any Ideas?

Thanks,
Preston  

Preston Baxter wrote:
>     Hi, I'm new to the list and have been I've been working with EMC 
> version 2.0.4 and noticed a possible bug with the backlash compensation 
> when jogging in manual mode.   I first select a jog increment, say .010 
> and jog in one direction  noting the movement on a dial indicator.  When 
> I reverse directions by one click(.010 increment), the backlash is not 
> taken up. Only when I jog at least one more increment does the backlash 
> compensation take affect.  It is like the compensation is delayed and 
> catches up on the next move.  The Backlash Comp does work properly in 
> MDI mode.  I have not yet checked it but assume it should work in Auto 
> mode as well.
>     I'm using the default stepper_inch.ini config, with only 
> modifications to the motor parameters.   Is there a setting somewhere I 
> am missing.  I worked with the old emc1 back in 1999 and the backlash 
> comp seemed to work fine in all modes.
>
> Thanks,
> Preston
>
>
>   


-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to