Len Shelton wrote: > Is anyone using EMC to drive a 2 axis (4 motor) hot wire foam cutter? If > not, does anyone have any insight on what it would require? The big problem is you have two, parallel, X-Y stages. EMC doesn't have the interpreter set up to handle two totally separate coordinate systems. This is the same problem for wire EDM. The back end that handles the motion control could do it with no trouble. Changing the interpreter to handle XY and UV doesn't sound so difficult until you realize there are all these offsets, smoothing, look ahead, etc. to consider.
Jon ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users