On 15 Dec 2007 at 7:16, [EMAIL PROTECTED] wrote: When I change from the pyVCP input to parport input the M66 does not work.
I changed net ArcStable motion.digital-in-01 <= pyvcp.arc-stable to net ArcStable motion.digital-in-01 <= parport.0.pin-10-in I can see ArcStable, motion.digital-in-01 and parport.0.pin-10-in change states in the watch window as I toggle the input on the breakout board but the M66 does not "see" it. my M66 line is M66 P1 L3 Q5 If I change the L word to 2 or 4 it breezes right through, a 1 or 3 and it times out even though I can see the motion.digital-in-01 change states... Any ideas??? Thanks John ------------------------------------------------------------------------- SF.Net email is sponsored by: Check out the new SourceForge.net Marketplace. It's the best place to buy or sell services for just about anything Open Source. http://ad.doubleclick.net/clk;164216239;13503038;w?http://sf.net/marketplace _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users