Dave Engvall wrote: > > Back to the shop: > First of all the home stuff in the .ini in case I've screwed something > up there: > > HOME_OFFSET 0.1 > HOME_SEARCH_VEL 0.1 > HOME_LATCH_VEL -0.01 > HOME_USE_INDEX YES > HOME_IGNORE_LIMITS YES
All fine. > > Now to halmeter: > not homing homing > axis.0.index-enable F T correct > axis.0.homing F T correct > motenc.0.enc-00-index-enable F F WRONG - this index enable pin should be connected to the axis index-enable pin, so they should both be the same at all times. > motenc.0.enc-00-index T T don't know > motenc.0.count xxxxx counting as expected > Xindex F F this is a signal name, but I don't know what you have the signal connected to. Stick the output of 'halcmd show' on a webpage somewhere (like http://pastebin.ca/ or http://pastebin.com ) and post the resulting URL so we can see what you have. I want to know why axis.0.index-enable isn't the same as motenc.0.enc-00-index-enable. I bet they're not connected. Regards, John Kasunich ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users