Dave Engvall wrote:
> 

> Back to the shop:
> First of all the home stuff in the .ini in case I've screwed something 
> up there:
> 
> HOME_OFFSET              0.1
> HOME_SEARCH_VEL     0.1
> HOME_LATCH_VEL          -0.01
> HOME_USE_INDEX         YES
> HOME_IGNORE_LIMITS     YES

All fine.

> 
> Now to halmeter:
>                                 not homing            homing
> axis.0.index-enable                    F                    T
correct
> axis.0.homing                        F                    T
correct
> motenc.0.enc-00-index-enable            F                    F
WRONG - this index enable pin should be connected to the axis 
index-enable pin, so they should both be the same at all times.

> motenc.0.enc-00-index                T                    T
don't know

> motenc.0.count                       xxxxx                counting
as expected

> Xindex                                F                    F
this is a signal name, but I don't know what you have the signal
connected to.

Stick the output of 'halcmd show' on a webpage somewhere (like 
http://pastebin.ca/ or http://pastebin.com ) and post the resulting
URL so we can see what you have.  I want to know why
axis.0.index-enable isn't the same as motenc.0.enc-00-index-enable.
I bet they're not connected.

Regards,

John Kasunich

-------------------------------------------------------------------------