On Fri, 2008-06-06 at 22:31 -0400, Stephen Wille Padnos wrote: > Check to see if the parameter "pluto.<whatever>.pwm.is-pdm" is set. If > so, try clearing that bit. That sets PDM or "Interleaved" PWM mode, > which operates similarly to a step generator - it outputs as high a > frequency as possible, to make it easier to average / filter (so you > don't need huge caps). Quite useful when you're trying to make a DAC, > but not so useful if you actually want fixed-period pulse width modulation. > > Of course that may not be the problem either :) > > - Steve > > Kirk Wallace wrote:
I know I set "pluto-servo.pwm.M.pwmdir 1". I didn't change "pluto-servo.pwm.is-pdm" so it should still be at the default, normal PWM, but it would be good for me to check anyway. Thanks. -- Kirk Wallace (California, USA http://www.wallacecompany.com/machine_shop/ Hardinge HNC/EMC CNC lathe, Bridgeport mill conversion, doing XY now, Zubal lathe conversion pending Craftsman AA 109 restoration Shizuoka ST-N/EMC CNC) ------------------------------------------------------------------------- Check out the new SourceForge.net Marketplace. It's the best place to buy or sell services for just about anything Open Source. http://sourceforge.net/services/buy/index.php _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users