After some more testing, this is what stepconf generates: net estop-out charge-pump.enable iocontrol.0.user-enable-out
This does not seem to work. I changed it to this: net estop-out iocontrol.0.user-enable-out setp charge-pump.enable 1 and as expected the CP starts as soon as EMC starts. This at least proved that the CP worked and my pin settings were correct. I then got rid of the setp and added: net zenable => charge-pump.enable and it works as I want. The CP goes on when I enable Axis. BTW, I love the MPG response - much better than Mach! My two lathe MPGs feel like they are directly connected now. That alone is enough to convince me to lose Mach :-) Thanks, Les ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users