John Kasunich wrote:

>[snip]
>
># scale factor converts RPM into DAC volts
>setp m5i20.0.dac-03-gain [SPINDLE]DAC_SCALE
>setp m5i20.0.dac-03-offset 0
>net spindle-on motion.spindle-on => m5i20.0.dac-03-enable
>  
>
Note that this example (and Toms) requires you to have a [SPINDLE] 
section in your ini file, and there must be a DAC_SCALE value in that 
section, like so:

[SPINDLE]
DAC_SCALE = 0.01

- Steve


------------------------------------------------------------------------------