2010/4/7 Alex Joni <[email protected]>

>
>
> On 4/7/2010 5:59 PM, Slavko Kocjancic wrote:
>
>> Hello...
>>
>> I just wonder how to measure if stepper lost steps and come to idea to use
>> home switch.
>> But I have no idea how to implement this. The idea is simple:
>> 1'st home the machine
>> 2'nd make test moves
>> 3'rd rehome machine
>>
>> In rehoming the EMC just need to read position before setting new home
>> position as is dictated in ini file. and the difference is measure of lost
>> steps...  or accuracy problems.
>>
>>
>>
> I would connect the home input to the probe input.
> Home first, then do some moves, then do a probe towards zero, and look at
> the point where the probe (home switch ) tripped.
>
> Note: you might have to have this connection inactive during homing (maybe
> it complains that the probe has been hit without a probing move..). You can
> achieve that in various ways (either an and2 with a digital output set by
> M5x or simply connect the home switch with the probe after you did the
> homing, etc).
>
> Regards,
> Alex
>
> Can't do that as I have home as limits.
------------------------------------------------------------------------------