On 25 April 2010 13:45, <[email protected]> wrote: > OK, that's a good idea. If there are two sensors spaced such that only > the longer element can activate them at the same time, the two outputs can > be ANDed together to provide the index.
I suppose it depends on how many pins are available. This is a parallel port system but I am assuming only a 2-axis (ie Lathe) one, so there might be enough pins for the job. My lathe has a milling head but even then I had enough pins for 3 axis limit/home switches and a 2-channel (pulse and index) spindle encoder. It was actually the pin shortage that persuaded me to switch to a 7i43 card configuration. (I wanted guard interlocks, e-stop detection, mill spindle encoder etc) -- atp ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users